Chinese Journal of Laboratory Medicine ; (12): 677-680, 2022.
Article in Chinese | WPRIM | ID: wpr-958571

ABSTRACT

Since the first edition of ISO15189"Medical laboratories: requirements for quality and competence" was published in 2003, it has been rapidly and widely used in the world under the promotion of the International Laboratory Accreditation Cooperation Organization (ILAC), and has become the basic standard for the quality management, capacity-building and capacity attestation of medical laboratories. The Mutual Recognition Arrangement (MRA) of ILAC for ISO15189 is the most authoritative international permit for examination results, which is accepted by international organizations. Since the establishment of ISO15189 medical laboratory accreditation system in 2004 in China, more than 530 medical laboratories have been accredited, which plays an important role in improving the quality and competence of medical laboratories in China, and improves the influence of Chinese medical laboratories in the world. ISO 15189:2012 is currently being revised by the International Organization for Standardization/Technical Committee on Clinical Laboratory Testing and in vitro diagnostic test systems (ISO/TC212). This revision will bring significant changes and the medical laboratory shall pay attention to these changes. In order to help medical laboratories understand the new ideas in advance, this paper summarizes and analyses the draft of the new international standards, and provides references for users.

2.
J. Bras. Patol. Med. Lab. (Online) ; 56: e3552020, 2020. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1143139

ABSTRACT

ABSTRACT COVID-19 was identified on December 31, 2019 in China, and has since been the subject of several studies. In the area of pediatrics, the infection appears to affect this population group more mildly when compared to adults. The present work shows the report of two cases of in patients in the pediatric age group, both aged 2 years, presenting their laboratory, clinical and radiological aspects. In this population, the virus's transmissibility seems to be related to symptom presentation, as the less symptomatic the patient presents the lower is transmissibility. The final interest of the presented cases is to demonstrate the good evolution that both patients in the pediatric age group showed, directing attention to the normality of laboratory tests and the presentation with a wide variety of differential diagnoses.


RESUMEN La Covid-19 fue identificada el 31 de diciembre de 2019 en China y ha estado bajo investigación desde entonces. La infección parece transcurrir de forma más leve en niños que en adultos. El presente trabajo muestra el reporte de dos casos de la infección con pacientes en la franja de edad pediátrica, ambos con 2 años de edad, presentando sus aspectos clínicos, radiológicos y de laboratorio. En esta población, es posible que la transmisibilidad del virus esté relacionada con la presentación de síntomas, ya que los pacientes menos sintomáticos tienen menor transmisibilidad. El interés final de los casos presentados es demostrar la buena evolución que ambos pacientes en el rango de edad pediátrico tuvieron, llamando atención para la normalidad de los testes de laboratorio y la presentación con gran variedad de diagnósticos diferenciales.


RESUMO A COVID-19 foi identificada no dia 31 de dezembro de 2019 na China e, desde então, tem sido objeto de diversos estudos. Na área da pediatria, a infecção parece afetar mais suavemente esse grupo populacional em comparação com os adultos. O presente trabalho apresenta o relato de dois casos de pacientes na faixa etária pediátrica, ambos com 2 anos de idade, mostrando seus aspectos laboratoriais, clínicos e radiológicos. Nessa população, a transmissibilidade do vírus parece estar relacionada com a apresentação dos sintomas, pois quanto menos sintomático o paciente se apresenta, menor a transmissibilidade. O interesse final dos casos relatados é demonstrar a boa evolução que os dois pacientes na faixa etária pediátrica apresentaram, direcionando a atenção para a normalidade dos exames laboratoriais e a apresentação com uma grande variedade de diagnósticos diferenciais.

3.
J. Bras. Patol. Med. Lab. (Online) ; 56: e3562020, 2020. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1143140

ABSTRACT

ABSTRACT In February 2020, the World Health Organization (WHO) named the infection with the new coronavirus, which appeared in December 2019 in China, as Covid-19, and defined it as a worldwide pandemic. There is not much evidence about the relationship between liver disease and Covid-19. Laboratory tests have played a fundamental role in confirming Covid-19, what is usually done by the polymerase chain reaction (PCR) sample. The present study reports the laboratory aspects of a patient with type C hepatitis diagnosed with Covid-19 with an unfavorable evolution, devoting special attention to laboratory tests that were almost normal.


RESUMEN En febrero de 2020, la Organización Mundial de la Salud (OMS) nombró a la infección por el nuevo coronavirus, que surgió en diciembre de 2019 en China, Covid-19, declarándola como pandemia mundial. No hay mucha evidencia sobre la relación entre enfermedades hepáticas y la Covid-19. Las pruebas de laboratorio han ocupado un lugar fundamental para confirmar la infección, lo que generalmente se hace por la muestra de reacción en cadena de la polimerasa (PCR). El presente estudio reporta los aspectos de laboratorio de un paciente con hepatitis C y diagnóstico de Covid-19 con evolución desfavorable, llamando la atención sobre pruebas de laboratorio con resultados casi normales.


RESUMO Em fevereiro de 2020, a Organização Mundial da Saúde (OMS) chamou a infecção pelo novo coronavírus, que surgiu em dezembro de 2019 na China, de COVID-19, definindo-a como pandemia mundial. Não há muitas evidências sobre a relação das doenças hepáticas e a COVID-19. Os exames laboratoriais vêm exercendo um papel fundamental na confirmação da infecção, que é feita geralmente pela amostra de reação em cadeia da polimerase (PCR). O presente estudo relata os aspectos laboratoriais de um paciente portador de hepatite do tipo C e diagnóstico de COVID-19 com evolução desfavorável, dando atenção especial para exames laboratoriais que estavam pouco alterados.

4.
Chinese Journal of Laboratory Medicine ; (12): E003-E003, 2020.
Article in Chinese | WPRIM | ID: wpr-811628

ABSTRACT

In December, the outbreak of a novel coronavirus (2019-nCoV) in Wuhan, China, has attracted extensive global attention. On January 20, 2020,the Chinese health authorities upgraded the coronavirus to a Class B infectious disease in the Law of the People's Republic of China on the Prevention and Treatment of Infectious Diseases, and considered it as Class A infectious diseases in disease control and prevention. On January 22, 2020, the 2019-nCoV nucleic acid detection test was listed as the diagnostic criteria in the "guidelines for diagnosis and treatment of pneumonia due to 2019-nCoV (Trial Version 2)" . Therefore, standardizing the operation process of the 2019-nCoV nucleic acid detection in clinical laboratories has become a top priority. It is of paramount importance to establish standard protocols for detection of the 2019-nCoV nucleic acids in clinical laboratories to improve the reliability of the results and ensure the biosafety of laboratory personnel.

5.
Chinese Journal of Laboratory Medicine ; (12): E001-E001, 2020.
Article in Chinese | WPRIM | ID: wpr-811626

ABSTRACT

With the outbreak and spread of the 2019 Novel Coronavirus pneumonia, laboratory biosafety has become increasingly prominent. The Society of Laboratory Medicine of Chinese Medical Association formulates this guideline with reference to Chinese National Recommendations and relevant documents. From the perspectives of Microbiology, Epidemiology, Case Definition, Safety Principles, Personal Precaution, Specimen Collection, Specimen Transport, Specimen Handling, Analysis, Post-Analysis and Emergencies, this guideline gives recommendations on biosafety precaution and biosafety protection. We hope that it can be practically implemented and continuously improved to ensure laboratory safety.

6.
Chinese Journal of Laboratory Medicine ; (12): 224-226, 2019.
Article in Chinese | WPRIM | ID: wpr-746273

ABSTRACT

In pace with the progressing and strengthening of administration requirement in standardization, biosafety, and third party accreditation for medical laboratories, internal and external environment itself are becoming important elements for total quality control. Laboratory management starts at planning and design. Making the six conceptions (normalization, safety, practicability, convenience, environment-friendliness, and good-looking) as the forerunners, taking more attention to and perfecting most of the details in the phase of planning and designing of a medical laboratory are therefore offered. The aims of informatization, automation, intellectualization, and hommization would be materialized through normatively partitioning clean, buffer and polluted areas, reasonably arranging the passageways of staff, stuff, air and information, and centrally laying out the electric, water, gases, air-condition, and monitoring, which would lay the good foundation for afterwards use and management of the laboratory.

7.
Chinese Journal of Laboratory Medicine ; (12): 547-553, 2018.
Article in Chinese | WPRIM | ID: wpr-806914

ABSTRACT

Objective@#To develop autoverification rules to assistant the verification of biochemical results, based on laboratory information management system. @*Methods@#Designed six kinds of autoverification logic rules according to the guidelines of Clinical and Laboratory Standards Institute (CLSI) AUTO-10A and Accreditation Criteria for the Quality and Competence of Medical Laboratories(ISO15189: 2012), based on in-control of the Internal Quality Control. Those rules inculds: logic disorder rules, critical value rules, warning value rules, delta check rules, relevant contradictions rules, abnormal mode rules, etc. Those rules was setted up in laboratory information management system of Dian Diagnostics. From October 2016 to April 2017, The status of autoverification was checked according to the items and bar code, and compared with clinical diagnostic and manual review. @*Results@#The passing rate of autoverification is over 65% when counted according to tests and is 45% when counted according to sample code, the coincidence rate is 92% with clinical diagnosis.In passing results of autoverification, the coincidence rate is 97.48% to 100% when campared with manual verification, and in not-passing results, the coincidence rate is 82.98% to 85.21%. @*Conclusion@#(1)Autoverification can verify half of routine biochemical test results by setting intelligent logics and rules. (2)Autoverification rules must be verified by a certain amount of test results before they can be formally applied. (3)Autoverification could improve the speed and efficiency of post-test steps.(Chin J Lab Med, 2018, 41: 547-553)

8.
Chinese Journal of Laboratory Medicine ; (12): 827-831, 2018.
Article in Chinese | WPRIM | ID: wpr-712222

ABSTRACT

Objective To investigate the reasons of unacceptable external quality assessment results for hemoglobin A1c (HbA1c), and improve quality level.Methods At the end of February 2017, five samples of HbA1c for external quality assessment (EQA) were sent to participated laboratories by post.After testing and reporting results by laboratories , the EQA organizer made statistical analysis and sent results back to laboratories.Meanwhile , messages would be sent to participants those had unacceptable EQA results . Investigating reasons of unacceptable results in 2017 through the EQA System based on web , which was developed by National Central for Clinical Laboratories , calculating the failure rate , analyzing the concrete reasons and combining EQA failure rates with current coefficient of variation .Results The EQA failure rate on HbA1c was 11.2%and reporting rates of reasons for failures was 70.4%(126/179).In the reasons for unacceptable results , technological (27.8%,35/126) and equipment's defects (26.2%,33/126) were the main reason categories , while malfunction ( 12.7%, 16/126 ) and methods defection ( 10.3%, 13/126 ) were the main reason subclass .The unexplainable results after survey account for 8.7%( 11/126 ) .In the group for coefficient of variation ( CV ) over 2%, the percentage of laboratories that had five samples get acceptable results was higher than that of group for CV less than 2%,and the percentage of laboratories that had at most four samples get acceptable results was lower than that of group for CV less than 2%.Conclusions The result of the reasons of unacceptable external quality assessment results for HbA 1c is generally satisfactory.The laboratory, manufacturer and EQA organizers should find and solve the working problems by analyzing EQA data , to improve the testing quality.

9.
Rev. Soc. Bras. Clín. Méd ; 15(4): 251-258, 20170000. ilus, graf
Article in Portuguese | LILACS | ID: biblio-877084

ABSTRACT

OBJETIVO: Apresentar um método prático de ensino e avaliar o grau de eficácia do aprendizado, comparando alunos que passaram pelo curso durante a graduação básica (sétimo semestre) e após 18 meses (décimo semestre), já no internato hospitalar. MÉTODOS: As vísceras conservadas por refrigeração, com coração, estruturas vasculares do mediastino, traqueia e pulmões, foram fixadas em suporte metálico apropriado. Os vasos supra- -aórticos foram ligados, e uma sonda de Foley foi introduzida retrogradamente para a infusão de água, permitindo a apresentação de procedimentos operatórios. Foram aplicados questionários a 40 alunos do sétimo e décimo semestre. As respostas foram submetidas à análise estatística. RESULTADOS: Foram demonstradas técnicas necessárias para o estabelecimento de circulação extracorpórea, confecção de enxerto aorta-coronária com segmento da artéria carótida obtido no mesmo bloco de vísceras, substituição da valva aórtica por prótese valvar sintética, correção de defeito previamente realizado no septo atrial, posicionamento dos vários tipos de eletrodos utilizados para a estimulação elétrica do coração, demonstração de técnicas empregadas para transplante cardíaco, simulação e correção de ferimentos do coração e da aorta. O grau de adequação da ferramenta avaliada foi positivo, com valores entre 55 e 95%, e houve retenção dos ensinamentos após 18 meses. Conclusão: Este método de ensino foi de fácil preparação e baixo custo, permitindo a realização de operações complexas e despertando interesse durante a graduação em Medicina.(AU)


OBJECTIVE: To present this practical teaching method, and assess the degree of learning effectiveness, comparing students who attended the course during basic undergraduation (seventh semester), and after eighteen months (tenth semester), when already in the Hospital internship. METHODS: Thoracic viscera, with heart, vascular structures of the mediastinum, trachea and lungs, preserved by refrigeration, were fixed in a metallic device. The supra-aortic branches were connected, and a Foley catheter was introduced backwards for water infusion, allowing the presentation of surgical procedures. Questionnaires were applied to 40 students of the seventh and tenth semesters; the answers underwent statistical analysis. RESULTS: The following techniques were demonstrated: establishment of cardiopulmonary bypass; coronary artery bypass grafting with carotid artery segment obtained in the same block of viscera; aortic valve replacement with synthetic valve; patch made with biological material in order to correct a defect previously held in the atrial septum; positioning of the various types of electrodes used for electrical stimulation of the heart; demonstration of techniques performed in cardiac transplantation and simulation and correction of both heart and aorta injuries. The degree of adequacy of such tool was positive, with values between 55 and 95%, and retention of what was taught after 18 months. CONCLUSION: This teaching method requires easy preparation and low cost, allowing the performance of complex operations, attracting medical students' interest.(AU)


Subject(s)
Humans , Animals , Cardiovascular Surgical Procedures/education , Education, Medical, Undergraduate/methods , Swine , Viscera/anatomy & histology , Anastomosis, Surgical/education , Surveys and Questionnaires , Extracorporeal Circulation , Extracorporeal Circulation/methods
10.
Chinese Journal of Laboratory Medicine ; (12): 727-732, 2017.
Article in Chinese | WPRIM | ID: wpr-668177

ABSTRACT

Objective To improve the quality of clinical biochemistry laboratory by quality indicators of pre-analytical,analytical,post-analytical phase and the whole process.Methods Analytical Phase:The Sigma values of items were calculated,applying the equation Sigma =(TEa%-Bias%)/CV%.Total allowable error (TEa) is from analyticalal specification defined in WS/T403-2012 of China,Bias% is from the evaluation results of National Center for Clinical Laboratory (NCCL) trueness verification PT series and CV% is from internal quality control data during the last 6 months in our lab.Normalized Sigma metrics plot was made to evaluate the analysis performance and the quality control strategies were designed accordingly.The quality goal indexes (QGI) were also calculated to propose improvement measures for items below 6 Sigma.Quality indicators of pre-,post-analytical and whole analytical phase,such as quality of specimen,critical value notification,critical value notification in time,TAT of hs-cTnT,TAT of emergency biochemical items,rewrite of laboratory reports and unacceptable performance in EQA-PT were measured in Sigma metrics too.The Sigma metrics changes before and after taking improvement measures were compared to conform the effectiveness.Results The average Sigma value of 17 biochemical tests was 5.29,of which 8 items (UA,K,ALP,CK,AMY,AST,TG,Na) achieved excellent to world class level (≥ 5 Sigma),6 items (LDH,Cre,TC,ALT,Mg,Glu) achieved marginal to good level (5 > Sigma ≥ 3),BUN performed poorly (3 > Sigma ≥ 2),Ca,TP performed unacceptably (Sigma < 2) with serious quality defects.The Sigma values of unacceptable specimen,critical value notification,critical value notification in time,unacceptable turn around time (TAT) of hs-cTnT,unacceptable turn around time (TAT) of emergency biochemical items,rewrite of laboratory reports,unacceptable performance in EQA-PT were 4.17,3.60,2.75,1.72,3.27,4.52,3.33 respectively,rising to 4.30,4.30,2.90,2.45,3.75,4.80,3.60 accordingly after improvement.Conclusions Sigma metrics is potentially an ideal approach for clinical biochemistry laboratories management,which is helpful to find out problems,put forward improvement measures,and confirm the effectiveness,so as to achieve the purpose of continuous quality improvement.

11.
Chinese Journal of Laboratory Medicine ; (12): 942-946, 2017.
Article in Chinese | WPRIM | ID: wpr-666134

ABSTRACT

Objective To establish the target measurement uncertainty(MU)of the routine coagulation assay according to the External Quality Assessment data(EQA)of routine coagulation assay. Methods Beijing Center for Clinical Laboratory(BCCL)established the target measurementuncertainty for routine coagulation assayswith the"up-down"methodon the basis of 93 clinical laboratoriesEQA datain BeijingThese assays includedActivated partial thromboplastine time(APTT), Fibrinogen(FBG), International Normalized Ratio(INR), Prothrombin time(PT), Thrombin time(TT)and D-dimer, Compared with CLIA′88,the proficiency of current coagulation assayswas observed.Results The MU of six routine coagulation assayscompared with CLIA ′88 showed that: The 90th percentile MU met the creteriain APTTof group B,FBG of group A&B&C,INR of group B and D-dimer of group B.The 75th percentile MU met the creteriainINR of group A&C,PT of group C.The medium met the creteriainAPTT of group A&C,PT of group A and INR of group D.Conclusions Target Measurement Uncertainty was establishedin routine coagulation assay by using EQA data only,whichcan simplify the procedure of determining MU and continuously update MU according to the frequency of EQA.It has good clinical practical value.However, the applicability of this method should also be considered.

12.
Chinese Journal of Laboratory Medicine ; (12): 907-910, 2017.
Article in Chinese | WPRIM | ID: wpr-666047

ABSTRACT

Accurate results in clinical laboratory are extremely important for patient safety.Quality control is the effective method to control the quality of testing process and ensure the patient safety.With the development of detection technology, the concept of quality control has changed.Clinical Laboratory Standards Institute(CLSI)has established a committee to formulate guidelines for quality control plan based on risk management in the laboratory, using the technology of risk management to develop individualized quality control plan.This article will introduce the understanding and practice of individualized quality control plan.

13.
Chinese Journal of Laboratory Medicine ; (12): 224-226, 2017.
Article in Chinese | WPRIM | ID: wpr-608546

ABSTRACT

Diverse technological advances in laboratory testing like DNA sequencing,have played important roles at the beginning of precision medicine.And the development of precision medicine will also require the advances of laboratory testing.However,with more new methods and biomarkers applied in clinical practice,the standardization of clinical laboratories testing is confronting great challenges.We will discuss the key challenges related to standardization of commercial reagents or systems and clinical tests,such as the choice of biomarkers,laboratory-developed tests and interpretation and reporting of the results.

14.
Chinese Journal of Laboratory Medicine ; (12): 421-424, 2017.
Article in Chinese | WPRIM | ID: wpr-618266

ABSTRACT

High-fat diet has led to rapid increase in population withdyslipidemia due to the improvement of living standard, which has seriously endangished people′s health.Blood lipid examination is the an important method to diagnose and monitordyslipidemia.Precision detection and proper management can effectively help doctor to diagnose and treat dyslipidemia.This article mainly introduced international and domestic guidelines about dyslipidemia and related progress as well as highlightin this field.Meanwhile, we provided several advices on dyslipidemia from various perspectives.Clinical laboratory related personnel should analyze the influenced factors on blood lipid test examination at pre-test, on-test and post-test and providebetter detection and managementfor blood lipid.

15.
J. bras. patol. med. lab ; 52(3): 149-156, May-June 2016. tab, graf
Article in English | LILACS | ID: lil-788993

ABSTRACT

ABSTRACT Introduction: Autoverification is the release of laboratory test results from clinical instruments to hospital interface, or to patients' records, with no human intervention. Verification rules are inserted in the middleware and/or in the laboratory information system (LIS), based on criteria established by the laboratory. As a result, it ensures that every result is consistently reviewed in the same way, improving the entire verification process and patient safety. Objective: Describe the implementation of autoverification of clinical chemistry tests results at the core laboratory of Hospital das Clínicas da Universidade Federal de Minas Gerais (HC/UFMG), Brazil. Material and methods: Twenty-six automated chemistry assays were chosen. They were fully automated including internal quality control, interfaced with LIS, available 24 hours a day, seven days a week. Rules were set up in the middleware and in the LIS. Instrument flags, evaluation of sample integrity, test linearity, delta check and critical values were used to construct the verification algorithms. Results: An autoverification algorithm was constructed; delta check values were calculated and defined, as well as automatic verification ranges. The results retained for manual verification followed a flowchart prepared for this purpose. Conclusion: Autoverification implementation led to a more consistent reviewing process of test results, efficiency and improved patient safety.


RESUMO Introdução: A verificação automática dos resultados consiste na liberação dos resultados dos exames diretamente do equipamento, sem intervenção humana. São inseridas regras para avaliar os resultados no middleware e/ou no sistema de informação laboratorial (SIL), com base em critérios estabelecidos pelo laboratório. A autoverificação uniformiza os critérios de liberação e melhora a eficiência no processo, garantindo a segurança do paciente. Objetivo: Descrever a implantação da autoverificação nos testes bioquímicos do menu de urgência no Serviço de Medicina Laboratorial (SML) do Hospital das Clínicas da Universidade Federal de Minas Gerais (HC/UFMG). Material e métodos: Foram configurados 26 testes bioquímicos disponíveis 24 horas por dia, plenamente interfaceados, inclusive o controle interno da qualidade. Definiram-se parâmetros e algoritmos usados para configuração do SIL e no middleware. No algoritmo elaborado para autoverificação, foram incluídos flags de equipamento, presença de interferentes na amostra, linearidade, delta check e valores críticos. Resultados O algoritmo de liberação automática de resultados, os valores de delta check, os intervalos de liberação automática e o fluxograma para liberação manual dos resultados retidos foram definidos e implantados. Conclusão: A implantação da autoverificação nos testes bioquímicos do menu de urgência no serviço possibilitou padronização e segurança na liberação dos resultados.

16.
International Journal of Laboratory Medicine ; (12): 224-225,234, 2016.
Article in Chinese | WPRIM | ID: wpr-603612

ABSTRACT

Objective To investigate the relationship among the average checking time of biochemistry results ,mental health of biochemistry results checkers and the rate of medical complains .Methods 258 biochemistry results checkers from 17 hospitals of Guangdong were tested by using symptom checklist(SCL‐90) ,biochemistry results checking time questionnaire and medical com‐plaints questionnaire .Results Compared with the national model data ,the mental health levels of biochemistry results checkers were worse relatively .The mental heath did not have gender difference ,however ,female checkers were significant worse than males in horror .The mental heath didn′t have gender difference between secondary and advanced technicians .However ,the junior techni‐cians were significant worse than technicians of other levels in obsession ,somatization ,anxiety ,depression and horror .The average checking time of biochemistry results was correlated with mental health of biochemistry results checkers .The average checking time of biochemistry results had relationship with the rate of medical complains .Conclusion The mental health conditions of biochemis‐try results checkers are bad .No mental health difference exists in gender .The junior technicians′mental heath are significant worse than secondary and advanced technicians .There are some relationships between the average checking time of biochemistry results , mental health of biochemistry results checkers and the rate of medical complains .

17.
Chinese Journal of Laboratory Medicine ; (12): 639-642, 2016.
Article in Chinese | WPRIM | ID: wpr-498587

ABSTRACT

Objective Through statistical analysis of specimen rejection reasons, aimed at finding the ways to reduce the failed specimen, making sure of continuous improvements in laboratory quality. Methods Department of Laboratory, Beijing ChaoYang Hospital, Capital Medical University had analyzed rejections specimen from October 2013 to September 2014 in CAP Q-TRACKS QT3 ( QT3: Laboratory Specimen Acceptability ) , and compared the laboratory rejection reasons with all laboratories of CAP. Results From October 2013 to September 2014, the total number of rejection specimen number was 2 367, in which 225 were incomplete labeled specimen/inadequate filled-out form, accounting for 9.5%.898 samples were rejected because of specimen clotted, accounting for 37.9%.The samples could not meet the requirement of specimen quantity of 254, accounting for 10.7%.Other reasons accounting for above 1%included wrong collection container, specimen hemolysis, lipemia or icteric specimen.After comparing the first five rejection reasons, Department of Laboratory, Beijing ChaoYang Hospital was found to be different with others laboratories of CAP.Conclusion The quality of the specimen is very important for the accuracy and reliability of the test results, and doing some positive statistical analysis and taking corrective measures can effectively reduce the unqualified specimen of the proportion.

18.
Chinese Journal of Laboratory Medicine ; (12): 477-480, 2016.
Article in Chinese | WPRIM | ID: wpr-497918

ABSTRACT

Since the Plan of Human Genome, the project as famous asthe Manhattan Project and the Apollo Project, has finished, it brings about rapid development in molecular diagnosis and leads to revolutionary breakthrough in in-vitro diagnostics directly. Molecular diagnostics have already applicatedextensively at present in tumor , genetic diseases, congenital anomalies, hematologic diseases, infectious disease, neuropsychiatric disorders and organ transplantation .The new molecular diagnostic technologies make much contributions to clinical decision in clinic practice ,whichmeanwhile brings with new challenges to medical laboratory (clinical laboratory) as well.The medical laboratory nowadays will face the demands of high quality and expectation from clinic as well as high risks .The risk consciousness, risk management and quality control should be enhanced in medical laboratory . Strict management and standardize operations should go through pre -examination processes, examination processes and post -examination processes.Every stuff should realizes the essence of “every number is a life”.Only in this way, the medical laboratory can appropriate the development of technology and medicine and the increasing demand of clinical diagnosis , treatment, prognosis, prediction and health management.

19.
Chinese Journal of Laboratory Medicine ; (12): 13-17, 2016.
Article in Chinese | WPRIM | ID: wpr-491479

ABSTRACT

Definiting the workflow and key link of the risk management in medical laboratory by FMEA.Identifying risk factors of the workflow and key link of blood coagulation test by the criteria for laboratory accreditation , such as ISO15189 recognition criteria and CAP laboratory accreditation inspection . Through the evaluation of the blood coagulation test , effective corrective actions and examining performance data periodically , the quality of the blood coagulation test can be improved continuously.

20.
Chinese Journal of Laboratory Medicine ; (12): 716-718, 2015.
Article in Chinese | WPRIM | ID: wpr-480510

ABSTRACT

Medical virtual simulation teaching environment is an advanced and complex combination of virtual simulation technology and medical technology training .As an advanced information technology , it has been attracting the attention of medical education researchers .Based on the characteristics of medical laboratory technology education , the virtual simulation experimental teaching center was established and a framework of the virtual simulation training environment was designed in the Department of Laboratory Medicine, Southern Medical University .Virtual simulation softwares and tool softwares were put into use widely in our experimental teaching .As it turns out, this simulated training environment has many merits such as risk-free safety , great efficiency , genuine learning experience and wide application potential , which partly overcomes the restriction of the teaching process brought by the condition of the practical operation and improves the teaching effect significantly .